@@ -16,21 +16,54 @@ Unreliable--constant packet loss.
the letter, audited code many times, cross-checked with RadioHead and RFM69
open-source drivers. No luck.
-Datasheet riddled with ambiguity.
-
ATmega328P runs at 5V; RFM69 3.3V. Suspect logic-level converter (LLC)
issues. High resistance. Not enough swing.
-2025-04: Ditched RFM69s. Switched to NRF24L01+ modules-- data pins 5V tolerant,
-no LLC required. Spent six weekends writing driver from scratch--clean-room.
-Works like a charm.
+2025-04: Ditched RFM69s. Switched to NRF24L01+ modules--data pins 5V tolerant,
+no LLC required. Spent six weekends writing a clean-room driver from scratch.
+Works like a charm.
+
+Basic security via xor cipher–good enough for a door behind a guard post and
+gate:
+
+```
+void xor(const char *k, const char *s, char *d, uint8_t n)
+{
+ int i;
+ for (i = 0; i < n; i++)
+ d[i] = s[i] ^ k[i];
+}
+```
+
+Resists replay attacks by cycling the key:
+
+```
+static inline void keygen(char *buf, uint8_t n)
+{
+ int i, imax;
+ uint8_t sreg;
+ uint16_t seed;
+
+ sreg = SREG;
+ cli();
+ seed = TCNT1;
+ SREG = sreg;
+
+ for (i = 0, imax = n - 1; i < imax; i++, seed++)
+ buf[i] = tab[(seed % tablen)];
+ buf[imax] = '\0';
+}
+```
+
+Protocol: FPM sends SYN. Servo responds with session key. Both xor-ed with
+static key. Session key used thereafter. Private command set authenticates
+endpoints.
2025-05: Wrote FPM drivers for R503 and FPM10A. UART RX sequence was
tricky--adopted Adafruit C++ FOSS implementation to C. R503 has built-in LEDs
and better form factor. Chose it for the lock.
-2025-06: Two PCB boards for FPM (front) and servo (back) controllers. Encrypted
-RF link between them.
+2025-06: Two PCBs for FPM (front) and servo (back) controllers.
<table style="border: none; width: 100%">
<tr style="border: none;">
@@ -68,7 +101,9 @@ Servo inrush current exceeds 1A. 0.3mm tracks cuts it too close.
Verdict: Functional but not practical. Battery dead in under 24 hours. Led to
[redesign](../fpm-door-lock-lp/) with proper power management.
-Commit:
-[f4b0b73](https://git.asciimx.com/smart-home/commit/?id=f4b0b734a595919cf451ab9448b06274c8e609a4)
-| Gerber: [gerber_back.zip](gerber_back.zip),
+Commit: <a
+href="https://git.asciimx.com/smart-home/commit/?id=f4b0b734a595919cf451ab9448b06274c8e609a4"
+class="external" target="_blank" rel="noopener noreferrer">f4b0b73</a> |
+Gerber: [gerber_back.zip](gerber_back.zip),
[gerber_front.zip](gerber_front.zip)
+